Zavos
IUI Catheter
The
Zavos IUI Catheter is a 5Fr. IUI catheter made out of clear polyethylene,
17cm in length. With an OD of 1.66mm and an ID of 0.65mm, a 5cm distal
segment with double side eyes and a rounded tip insures a very smooth
entry through the cervix with minimal disturbance to the endometrial
stroma. This is accomplished with 11cm of marked catheter shaft with
7Fr. in diameter for superior and secure handling. A proximal Luer
lock allows for proper connection with a syringe. The Zavos IUI catheter
allows for the sperm to bypass the cervix so that an increased number
of high quality sperm can reach the uterine cavity and the fallopian
tubes.
Features
- Soft
inner catheter with Double Side Eyes and Rounded Tip
- Super
smooth entry to the endometrial stroma
- Outer
shaft is marked in 1cm segments
- Standard
Luer Lock
- Length:
17cm
- OD:
2.3mm Shaft (13cm length); 1.66mm Distal (5cm length)
- ID:
0.65mm
Indications
for use of the Zavos IUI catheter
- Intrauterine
insemination
Contraindications
for use of the Zavos IUI catheter
- Not
intended for IVF, GIFT or other intra fallopian tube procedures.
- Should
not be used in the presence of cervical infection.
- Should
not be used in the presence of or after recent pelvic inflammatory
disease.
Warnings
- Always
use washed spermatozoa when performing intrauterine artificial
insemination, or intracervical artificial insemination.
The introduction of unwashed spermatozoa into the uterus will
almost always result in severe adverse reactions, which may include
anaphylactic shock. Please refer to the SpermPrep™
and ZSC™II methods shown in this catalog for
preparing spermatozoa for intrauterine insemination before performing
this procedure.
Zavos
Artificial Insemination (AI) Kit
The
Zavos AI Kit offers the ultimate solution for the physician who
wants to perform artificial inseminations in the office. This kit
includes everything any physician would need to perform the in-office
AI, including one vial for semen collection, one 5mL syringe, and
one TomCat AI catheter. The Zavos Artificial Insemination Kits
comes completely sterile and are packaged individually for your
convenience.
Indications
for use of the Zavos AI Kit
- Intrauterine
insemination by Physician
Contraindications
for use of the Zavos IUI catheter
- Not
intended for IVF, GIFT or other intra fallopian tube procedures.
- Should
not be used in the presence of cervical infection.
- Should
not be used in the presence of or after recent pelvic inflammatory
disease.
Top
of Page
Insemination
Device
The
Insemination Device includes one 5mL syringe and one TomCat AI catheter.
The Insemination Device comes completely sterile and are
packaged individually for your convenience.
Indications
for use of the Zavos AI Kit
- Intrauterine
insemination by Physician
Contraindications
for use of the Zavos IUI catheter
- Not
intended for IVF, GIFT or other intra fallopian tube procedures.
- Should
not be used in the presence of cervical infection.
- Should
not be used in the presence of or after recent pelvic inflammatory
disease.
Top
of Page
Makler™
Cannula for Intrauterine Insemination (IUI)
Atraumatic:
This disposable and sterilized cannula is semi-rigid with a rounded
tip, and therefore atraumatic during the insemination procedure.
Optimal
size: Suitable for uterine cavities
of all sizes. A small volume of washed and concentrated sperm
is sufficient for insemination (0.5 ml.) an important fact in cases
of oligospermic specimens.
Flexibility:
Optimal rigidity enables the cannula to fit itself to the curvature
of the uterus.
Cervix
sealing: The flared base
shape, serves to seal the cervix to prevent the back-flow of the
injected contents.
Suggestions
for the preparation of the injected contents
Sperm
preparation for IUI can be performed via the use of the SpermPrep™
filtration method or the ZSC™ methods. For further
information on how to better employ these methods in your lab or
your practice please refer to those products in this prospectus.
Also, for further information, if necessary, please call ZDL,
Inc., or your local distributor.
For
best results it is recommended
to use this cannula together with The Makler Insemination Device.
The
Makler Cannula (Catheter) is available
also in a short size for intra-cervical insemination.
The
Tom Cat IUI catheter is designed with a flexible body which enables
the catheter to fit itself to the curvature of the uterus. It is
relatively a small and maneuverable IUI catheter, 4.5" length, 3.5Fr.
and open end. The Tom Cat IUI catheters are sterile, individually
packaged and are sold in 50 catheters per box
Indications
for use of the Tom Cat catheter
- Intrauterine
insemination
Contraindications
for use of the Tom Cat catheter
- Not
intended for IVF, GIFT or other intra fallopian tube procedures.
- Should
not be used in the presence of cervical infection.
- Should
not be used in the presence of or after recent pelvic inflammatory
disease.
Warnings
- Always
use washed spermatozoa when performing intrauterine artificial
insemination, or intracervical artificial insemination.
The introduction of unwashed spermatozoa into the uterus will
almost always result in severe adverse reactions, which may include
anaphylactic shock. Please refer to the SpermPrep™
and ZSC™ methods shown in this catalog for
preparing spermatozoa for intrauterine insemination before performing
this procedure.
Caution
- These
catheters are not designed to be reused or resterilized.
Destroy after single use.
Adverse
Reactions
- No
adverse reactions associated with the Tom Cat IUI Catheter have
been reported. However, as with any instrument which is
passed through the internal cervical os, mild cramping may be
expected.
Makler
Insemination Device
The
device is composed of two main parts:
- a
semi-rigid atraumatic cannula that can be fitted to the tip of
1.0 ml tuberculin syringe. There are two versions of this
cannula: the long one is for intrauterine insemination and the
short one is for intracervical deposition of spermatozoa.
- A
carrier to hold the syringe and to press the cannula against the
outer cervix to prevent leakage of the injected contents.
Mode
of Employment:
About
0.2-0.5 ml of the contents prepared in a test tube is aspirated
through the cannula into the syringe and the latter is inserted
into the tip of the carrier. Under direct speculum visualization
the cannula is introduced into the cervical canal or uterine cavity
according to type used. Until the external os is entirely
obliterated by the flared base of the cannula. A tenaculum
is not required unless the uterus is hyper flexed and pulling in
order to straighten its angle is needed. The clamp is fixed
to the outer brim of the speculum and the tension of the spring
is adjusted so that the cannula is gently pressed against the cervical
outlet. The contents are now slowly injected and the sealing
mechanism prevents the backflow of the injected material.
The patient can be left in a supine position for 10-20 minutes before
the set is removed.Suggestions
for preparation of the injected contents
Raw
seminal fluid should not be injected either to the uterine cavity
or to the cervical canal, as this may irritate and induce cramps
and fainting. Only properly prepared sperm should be used
and this can be achieved by using either the SpermPrep™
filtration method or the ZSC™ technology swim-up/swim-down
technique (ZSC™ and ZSC™ II)with properly
formulated SpermPrep™ medium. Oligospermic specimens
need to be centrifuged at 300 g for 10 minutes and the concentrated
pellet be mixed and injected.
Indications.
The
use of this technique with the Makler Insemination Device is suggested
in the following cases:
- Infertility
due to subfertile oligo-asthenospermic specimens.
- Poor
post coital tests due to cervical hostility, low semen volume
or antisperm antibodies within cervical mucus.
- To
increase probability of fertilization in conjunction with induction
of ovulation.
- Cases
of unexplained infertility.
- To
increase successful rate in donor insemination or to enable using
one specimen for several different patients.
|